Evidence map›Paper›PMID 42077378›Full record

ArticleEuropean heart journal. Digital health2026

Artificial intelligence-enhanced wearable technology enables ventricular arrhythmia prediction.

Maarten Z H Kolk, Diana My Frodi, Joss Langford, Peter Karl Jacobsen, Niels Risum, Tariq O Andersen, Hanno L Tan, Jesper Hastrup Svendsen, Reinoud E Knops, Søren Zöga Diederichsen and 1 more

Abstract read
In one paragraph

Article in European heart journal. Digital health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Maarten Z H KolkDepartment of Clinical and Experimental Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.ORCID https://orcid.org/0000-0003-0624-1510
Diana My FrodiDepartment of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100, Copenhagen, Denmark.ORCID https://orcid.org/0000-0001-7074-5575
Joss LangfordActivinsights Ltd., Unit 11, Harvard Industrial Estate, Kimbolton, Huntingdon PE28 0NJ, UK.ORCID https://orcid.org/0000-0002-3204-5866
Peter Karl JacobsenDepartment of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100, Copenhagen, Denmark.ORCID https://orcid.org/0000-0002-1520-8774
Niels RisumDepartment of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100, Copenhagen, Denmark.ORCID https://orcid.org/0000-0002-0357-9164
Tariq O AndersenDepartment of Computer Science, University of Copenhagen, Universitetsparken 1, 2100, Copenhagen, Denmark.ORCID https://orcid.org/0000-0002-9342-5520
Hanno L TanNetherlands Heart Institute, Moreelsepark 1, 3511 EP, Utrecht, The Netherlands.
Jesper Hastrup SvendsenDepartment of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100, Copenhagen, Denmark.
Reinoud E KnopsDepartment of Clinical and Experimental Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Søren Zöga DiederichsenDepartment of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100, Copenhagen, Denmark.
Fleur V Y TjongDepartment of Clinical and Experimental Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.ORCID https://orcid.org/0000-0001-9608-0081

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: Patterns in physical behaviour may be associated with an increased risk of ventricular arrhythmia. We examined associations between temporal dynamics in physical behaviour measured through wearable technology and the risk of ventricular arrhythmia. Methods and results: The multicentre, prospective SAFEHEART study recruited 303 patients with an implantable cardioverter-defibrillator (ICD) from May 2021 to September 2022. Continuous physical behaviour data were collected over 365 consecutive days and nights using wearable accelerometers. We characterized each 28-day behavioural time series using statistical summary indices and deep representations learned by neural networks. Logistic regression analyses were used to estimate the associations between physical behaviour and the subsequent risk of ventricular arrhythmia as detected by ICD and treated appropriately. Predictive performance was assessed using k-fold cross-validation and quantified by the area under the receiver operating characteristic curve (AUROC). From the SAFEHEART cohort, 277 patients and 56 ventricular arrhythmia were analysed, contributing to a total of 64 995 days of behavioural data. Reduced numbers of daily physical activity bouts and low day-to-day variation in sleep characteristics were associated with an increased risk of an arrhythmic event. Deep representations improved the predictive performance, with an AUROC of 0.74 ± 0.05, compared with statistical summary indices with an AUROC 0.67 ± 0.14 ( Conclusion: Our findings suggest that behavioural patterns captured through wearable technology are independently associated with ventricular arrhythmia, particularly when these are characterised by deep representations.

Indexed as

Artificial intelligenceImplantable cardioverter-defibrillatorVentricular arrhythmiaWearable activity tracker

Identifiers

PMID42077378
PMCPMC13131985

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.