Evidence map›Paper›PMID 42085342›Full record

ArticleOphthalmic research2026

The AROMA Dataset for Automatic Detection of Artifact Type and Severity in Retinal Optical Coherence Tomography Angiography.

Lucas Szwarcberg, Atif Anwer, Alexandre Gozlan, Paul Drouard, Pierre-Henry Gabrielle, Catherine Creuzot-Garcher, Fabrice Mériaudeau, Louis Arnould

Abstract read
In one paragraph

Article in Ophthalmic research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lucas SzwarcbergDepartment of Ophthalmology, Dijon University Hospital, Université Bourgogne Europe, Dijon, France.
Atif AnwerICMUB UMR 6302, CNRS, Université Bourgogne Europe, Dijon, France.
Alexandre GozlanDepartment of Anaesthesiology, APHM North University Hospital, Marseille, France.
Paul DrouardDepartment of Ophthalmology, Dijon University Hospital, Université Bourgogne Europe, Dijon, France.
Pierre-Henry GabrielleDepartment of Ophthalmology, Dijon University Hospital, Université Bourgogne Europe, Dijon, France.
Catherine Creuzot-GarcherDepartment of Ophthalmology, Dijon University Hospital, Université Bourgogne Europe, Dijon, France.
Fabrice MériaudeauICMUB UMR 6302, CNRS, Université Bourgogne Europe, Dijon, France.
Louis ArnouldDepartment of Ophthalmology, Dijon University Hospital, Université Bourgogne Europe, Dijon, France, louis.arnould@chu-dijon.fr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn recent years, retinal vascular imaging has attracted growing interest and is experiencing rapid technological advancements in imaging modalities such as swept-source optical coherence tomography angiography (SS OCT-A). OCT-A enables precise, noninvasive, quantitative measurements of retinal vascularization. However, it is also prone to artifacts that are challenging to detect and can significantly limit diagnostic accuracy and biomarker reliability.

methodsWe present a dataset of en face retinal SS OCT-A images, labeled by artifact type and severity. Each patient's OCT-A scan consists of 14 images that are graded by multiple experts and assigned corresponding artifact labels with an overall quality grade. We also report results for two deep-learning binary classification models trained on the dataset: one based on image compression via principal component analysis (PCA) and the other using a six-channel tensor.

resultsThe dataset comprised 281 OCT-A scans from 115 anonymized patients. The PCA-based model achieved a precision of 87% for image quality classification, while the six-channel model achieved 97%.

conclusionUsing a curated dataset of en face SS OCT-A images with detailed artifact annotations, we trained a deep-learning model capable of high-precision image quality classification. These results demonstrate the feasibility of using task-specific artificial intelligence for quality assessment based on artifact detection in retinal imaging.

Indexed as

ArtifactsFluorescein AngiographyRetinal DiseasesRetinal VesselsTomography, Optical CoherenceDeep LearningFemaleFundus OculiHumansReproducibility of ResultsArtifactsDeep learningOptical coherence tomography angiographyRetinal imaging

Identifiers

PMID42085342
PMCPMC13229489

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.