Evidence map›Paper›PMID 42147935›Full record

ArticleQuantitative imaging in medicine and surgery2026

Photon-counting detector of the ophthalmic artery: impact of virtual monoenergetic levels, reconstruction kernel, and quantum iterative reconstruction (QIR) on image quality.

Sangying Lv, Haijuan Wu, Xuzhong Ying, Jianfeng Yang, Zhenhua Zhao, Haijia Mao

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sangying LvDepartment of Radiology, Shaoxing People's Hospital, Shaoxing, China.
Haijuan WuDepartment of Radiology, Shaoxing People's Hospital, Shaoxing, China.
Xuzhong YingDepartment of Radiology, Shaoxing People's Hospital, Shaoxing, China.
Jianfeng YangDepartment of Radiology, Shaoxing People's Hospital, Shaoxing, China.
Zhenhua Zhao *Department of Radiology, Shaoxing People's Hospital, Shaoxing, China.
Haijia Mao *Department of Radiology, Shaoxing People's Hospital, Shaoxing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The ophthalmic artery (OA), a major branch of the internal carotid artery that supplies orbital vital structures and can serve as a potential biomarker for ocular and systemic diseases, is challenging to visualize due to its small diameter, tortuous course, and complex anatomy. Photon-counting detector computed tomography (PCD-CT) outperforms conventional energy-integrating detector computed tomography (CT) in orbital vascular imaging; however, relevant key reconstruction parameters for OA visualization have yet to be investigated. This study aimed to identify the optimal PCD-CT reconstruction parameters, including virtual monoenergetic imaging (VMI) level, reconstruction kernel, and quantum iterative reconstruction (QIR), for maximizing OA image quality. Methods: A total of 17 patients (33 OAs) underwent ultra-high-resolution carotid PCD-CT angiography. Axial images were reconstructed at 40-120 keV (20 keV increments), using reconstruction kernels [body vascular convolution (Bv) 40, 48, 56, 64, and 72] and QIR levels 3 and 4. For objective analysis, two blinded radiologists placed standardized regions of interest (ROIs) in the OA, intraorbital fat, and medial rectus muscle belly, respectively. Mean arterial signal intensity attenuation (MA), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) were measured. Two blinded radiologists subjectively assessed overall image quality, vessel sharpness, and diagnostic assess-ability (using 5-point Likert scales). Linear mixed-effects models (LMMs) identified optimal parameter combinations via a composite z-score. Friedman and Dunn's tests were used to compare the top protocols. Results: The objective analysis revealed that the MA, SNR, and CNR showed an inverse relationship with keV. The highest CNR was obtained at 40 keV using Bv40 and QIR4. Lower keV levels (40-60 keV) increased the MA by 136-195%, but decreased the SNR by 54.9-67.5% compared with higher keV levels (100-120 keV). The MA values initially increased with higher Bv values, peaking at 491.53±371.75 Hounsfield unit (HU) for Bv64. Conversely, both the SNR and CNR demonstrated a consistent decreasing trend with increasing Bv values. Sharper kernels (Bv72) decreased the CNR by 56.9% but increased the MA by 54.3% compared with smoother kernels (Bv40). QIR4 exhibited higher SNR and CNR values compared to those reconstructed with QIR3 (P<0.05). The MA values were similar between QIR3 and QIR4. QIR4 enhanced the SNR by 36.5%, the CNR by 37.6%, and the MA by 0.94% compared with QIR3. The subjective analysis showed that 40 keV/Bv56/QIR4 achieved perfect median scores (5/5) across all subjective features, significantly outperforming lower reconstruction kernel protocols (Bv40: median 1-2, Bv48: median 3-4; P<0.0001). Despite a superior objective CNR at Bv40, subjective ratings favored the Bv56 balanced noise-contrast profile. Subjective consensus identified 40 keV, Bv56 kernel, and QIR4 as optimal. Conclusions: For PCD-CT visualization of the OA, a VMI level of 40 keV combined with the Bv56 kernel and QIR4 provides the optimal balance between objective metrics and subjective radiologist preference, enhancing vascular delineation while controlling image noise. This protocol may improve diagnostic confidence in assessing small-caliber orbital vasculature.

Indexed as

computed tomography angiography (CT angiography)image qualityophthalmic artery (OA)Photon-counting detector computed tomography (photon-counting detector CT)virtual monoenergetic imaging (VMI)

Identifiers

PMID42147935
PMCPMC13178328

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.