Evidence map›Paper›PMID 42164729›Full record

ReviewCardiovascular diagnosis and therapy2026

Artificial intelligence-enhanced electrocardiography for acute myocardial infarction detection: a systematic review.

Yangyoun Lee, Jung Hwan Ahn, Hyoung-Mo Yang

Abstract readReview
In one paragraph

Review in Cardiovascular diagnosis and therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yangyoun LeeDepartment of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.ORCID https://orcid.org/0009-0002-9228-4006
Jung Hwan AhnDepartment of Emergency Medicine, Ajou University School of Medicine, Suwon, Republic of Korea.
Hyoung-Mo YangDepartment of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.ORCID https://orcid.org/0000-0003-3602-9772

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Artificial intelligence (AI) shows promise for improving electrocardiogram (ECG)-based acute myocardial infarction (AMI) detection, but clinical readiness remains uncertain. We aimed to conduct a systematic synthesis informed by a structured search of AI-enhanced ECG systems to evaluate their performance, validation quality, and implementation readiness. Methods: We conducted a structured search of PubMed and Embase (publication date limits: January 1, 2017, to August 31, 2025; last searched: February 18, 2026) for English-language human studies that developed or validated AI models for ECG-based AMI diagnosis, extracting data on architectures, clinical applications, validation approaches, and performance metrics; we excluded non-original publications and studies that were non-English or non-human studies or did not use ECG input or did not address AMI diagnosis. Results: We included 88 studies; the total number of participants was not estimable because sample sizes were inconsistently reported across studies. Among 88 identified studies, convolutional neural networks predominated (51/88, 58%). Most studies were retrospective (80/88, 91%) and used 12-lead ECG (64/88, 73%). Reported performance varied widely [area under the receiver operating characteristic curve (AUROC), 0.700-0.999; sensitivity, 67.7-100.0%; specificity, 73.3-100.0%], with promising results for detecting subtle ischemic patterns in non-ST-elevation and occlusion myocardial infarction (OMI). However, only 33/88 (37.5%) performed external validation. Public datasets were used in 50/88 (57%) and institutional patient cohorts in 43/88 (49%); several studies used both sources. More complex architectures did not consistently demonstrate superior accuracy, though heterogeneity in study designs limits definitive conclusions. Conclusions: AI demonstrates substantial technical potential for AMI detection, particularly for subtle ischemic patterns. However, critical gaps impede clinical deployment: insufficient external validation, reliance on curated datasets with limited generalizability, absence of standardized evaluation frameworks, and insufficient evidence on patient-centered outcomes. Future research must prioritize prospective multicenter validation, standardized benchmarks with rigorous reference standards, and real-world implementation studies examining clinical outcomes and workflow integration. Technical feasibility is established; clinical impact now depends on validation rigor and pragmatic deployment.

Indexed as

Artificial intelligence (AI)electrocardiographymachine learning (ML)myocardial infarction

Identifiers

PMID42164729
PMCPMC13184927

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.