Evidence map›Paper›PMID 42202269›Full record

ArticleJMIR rehabilitation and assistive technologies2026

Accuracy in the Estimation of Self-Reported Knee Brace Wear Time in Young Adults With a Symptomatic Knee Following ACL Reconstruction: Secondary Analysis of a Pilot Randomized Controlled Trial.

Matthew Savage, Benjamin F Mentiplay, Harriette Slater, Fernanda Serighelli, David L Carey, Jamon L Couch, Andrea M Bruder, Adam G Culvenor

Abstract read
In one paragraph

Article in JMIR rehabilitation and assistive technologies, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Matthew SavageLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0009-0009-0807-6249
Benjamin F MentiplayLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0000-0002-4360-8310
Harriette SlaterLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0009-0006-3740-6807
Fernanda SerighelliLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0000-0002-0057-8596
David L CareyLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0000-0001-6388-8957
Jamon L CouchLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0009-0009-6481-041X
Andrea M BruderLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0000-0001-5422-5756
Adam G CulvenorLa Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Plenty Rd, Bundoora, Melbourne, Victoria, 3086, Australia, +61 3 9479 5116.ORCID http://orcid.org/0000-0001-9491-0264

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Knee braces may improve symptoms and physical function following anterior cruciate ligament reconstruction (ACLR). However, their effectiveness depends on adherence, which typically relies on self-reported wear time, prone to recall and response bias. Objective measures (eg, temperature sensors), validated in footwear and orthotics research, offer a potentially more accurate alternative to self-reporting. Despite this, there is no research comparing self-reported and sensor-measured wear times in a knee brace. Objective: This study aimed to determine how well self-reported wear times reflect sensor-measured data in a slim-fit knee brace. Methods: Young adults (aged 18-45 years), 1-8 years post-ACLR, with a symptomatic knee (the 4 Knee injury and Osteoarthritis Outcome Score subscales [KOOS4] score <80/100) wore a slim-fit brace during a 6-week feasibility trial. This study reports a secondary analysis of participants allocated to the brace group. Self-reported wear times were recorded in daily logs. An undisclosed, embedded temperature sensor recorded temperature every 10 minutes. A wear detection algorithm identified brace donning and doffing. These data were used to calculate aggregated measures (ie, summary measures across the entire 6-week intervention period, including cumulative wear time, average daily wear time, and total number of days worn) and repeated measures (daily wear duration, 3- and 7-day rolling averages, where wear time is averaged over consecutive days). Agreement between self-reported and sensor-based measures was assessed using concordance correlation coefficients (CCCs) and limits of agreement (LoA). Results: Of the 14 randomized participants, 10 (30% male [n=3]; mean age: 33, SD 6 years; time post-ACLR: 4, SD 1 years) had both temperature sensor and self-reported wear data. Six participants (60%) underreported average daily wear time (mean 29, SD 24 minutes across all 10 participants), while nine (90%) overreported the number of days worn (mean 9, SD 6 days across all 10 participants). Daily wear time showed moderate agreement between the sensor and self-reporting (CCC 0.70, 95% CI 0.58-0.79), but wide LoA (-223 to 217 minutes). Using 3- or 7-day rolling averages narrowed LoA (-47 to 36 minutes per day and -14 to 10 minutes per day, respectively) and slightly improved CCCs (0.74, 95% CI 0.58-0.85, and 0.73, 95% CI 0.51-0.86, respectively). Greater agreement was observed with more aggregated outcomes; for total 6-week wear time, the CCC was 0.84 (95%CI 0.50-0.95). When expressed as daily average wear time, the CCC was excellent (0.92, 95% CI 0.73-0.98), although daily LoA remained wide (-68 to 32 minutes), indicating substantial individual variability between self-reported and sensor-based measures. For the total number of days worn, the CCC was moderate (0.64, 95% CI 0.15-0.88) and LoA was wide (-10 to 22 days). Conclusions: Self-reported daily brace wear time is inaccurate compared to wear time measured by the temperature sensor. Aggregated data and rolling averages showed better agreement. Future intervention studies should consider objective adherence measures. Failing this, averaging self-reported wear time across the intervention period could improve accuracy.

Indexed as

knee braceknee injuryknee osteoarthritisphysiotherapyrehabilitationsensorwearable technology

Identifiers

PMID42202269
PMCPMC13215634

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.