Evidence map›Paper›PMID 42210140›Full record

ArticleBMC medical imaging2026

Cardiac echocardiographic analysis with multi-scale effective fusion module: a novel stroke prediction approach.

Jiachun Xie, Dianhuan Tan, Tingting Zheng, Yun Chen, Liya Wei

Abstract read
In one paragraph

Article in BMC medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jiachun Xie *Shenzhen Key Laboratory for Drug Addiction and Medication Safety, Department of Ultrasound, Institute of Ultrasonic Medicine, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen, Guangdong, 518036, P. R. China.ORCID 0009-0008-8024-5484
Dianhuan Tan *Shenzhen Key Laboratory for Drug Addiction and Medication Safety, Department of Ultrasound, Institute of Ultrasonic Medicine, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen, Guangdong, 518036, P. R. China.ORCID 0009-0003-1899-1818
Tingting ZhengShenzhen Key Laboratory for Drug Addiction and Medication Safety, Department of Ultrasound, Institute of Ultrasonic Medicine, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen, Guangdong, 518036, P. R. China. kyzs_018@126.com.ORCID 0000-0003-0424-0231
Yun ChenShenzhen Key Laboratory for Drug Addiction and Medication Safety, Department of Ultrasound, Institute of Ultrasonic Medicine, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen, Guangdong, 518036, P. R. China. yunchen@sphmc.org.ORCID 0000-0002-4975-5637
Liya WeiShenzhen Key Laboratory for Drug Addiction and Medication Safety, Department of Ultrasound, Institute of Ultrasonic Medicine, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen, Guangdong, 518036, P. R. China. 68173650@qq.com.ORCID 0009-0005-8767-2567

Funding

National Key Research and Development Program of China 2023YFC3402605Peking University Shenzhen Hospital LCYJZD2021010the Natural Science Foundation of Guangdong Province 2022A1515010986, 2022A1515010296the Sanming Project of Medicine in Shenzhen SZSM202111011the Science and Technology Project of Shenzhen JCYJ20230807095209018, JCYJ20210324110211031, JCYJ20210324131402008, KXCFZ202002011010487the Shenzhen Key Medical Discipline Construction Fund SZXK051
6 · The paper itself

Abstract

backgroundStroke remains a leading cause of death and disability, and early risk stratification is critical for prevention. Existing models based only on clinical factors may miss subtle cardiac structural and hemodynamic information visible on echocardiography. We aimed to develop a multimodal stroke prediction model integrating multi-view echocardiographic images and clinical indicators.

methodsIn this retrospective study, 712 hypertensive patients (10,992 echocardiographic images; 27 clinical variables) were included. Long-axis, short-axis, and apical four-chamber views were analyzed. We developed a Multi-Scale Effective Fusion (MSEF) module combining Global Feature Fusion, Multi-Feature Reconstruction, Channel Attention, and Positional Attention to improve multi-scale feature representation. Imaging features were integrated with clinical variables to build multimodal models. Model performance was evaluated on validation and test sets using accuracy, precision, recall, and F1 score.

resultsThe MSEF-based imaging model outperformed comparator fusion variants and achieved an accuracy of 76.8% and an F1 score of 64.7% on the test set. After integrating clinical indicators, performance further improved, with a test accuracy of 80.2% and an F1 score of 72.1%.

conclusionsThe proposed MSEF-based multimodal framework improves stroke risk prediction by effectively combining echocardiographic and clinical information, and may support earlier risk identification and clinical decision-making.

Indexed as

EchocardiographyHypertensionStrokeAgedFemaleHumansMaleMiddle AgedRetrospective StudiesRisk AssessmentAttention mechanismsEchocardiographic imagesFeature fusionMulti-scale effective fusionStroke prediction

Identifiers

PMID42210140
PMCPMC13411767

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.