ArticleIUCrJ2026
Atomic resolution cryo-EM at 200 keV.
Article in IUCrJ, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- CryoEM in the fast lane of structural biology.IUCrJ · 2026Review
- Cryo-EM: the revolution continues.IUCrJ · 2026Review
- A cost-effective 200 kV cryo-EM core facility for high resolution single particle analysis.Methods in microscopy · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Atomic resolution in cryo-electron microscopy was first demonstrated six years ago. This was accomplished using 300 kV electron microscopes equipped with new hardware that provided narrower energy spread, aberration correction and energy filtering. Here, we report the achievement of 1.24 Å atomic resolution on an upgraded 200 kV electron microscope featuring a cold field emission gun, a high-resolution objective lens polepiece and an energy filter. These components transform the instrument into a cost-effective single-particle cryo-EM platform with performance comparable to that of significantly more expensive 300 kV systems. The microscope can also be operated at 100 kV and by using a high-speed hybrid-pixel detector we were able to reach sub-2 Å resolution.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.