Evidence map›Paper›PMID 42294843›Full record

ArticleJournal of paediatrics and child health2026

The Accuracy of a Commercial Wearable Neonatal Home-Monitoring Device: A Simulation Study.

Amelia N Noone, Danielle N Bailey, Tara M Crawford, Shem Richards, Chad C Andersen, Michael J Stark

Abstract read
In one paragraph

Article in Journal of paediatrics and child health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amelia N NooneRobinson Research Institute, College of Health, Adelaide University, Adelaide, South Australia, Australia.ORCID https://orcid.org/0000-0002-1174-1870
Danielle N BaileyRobinson Research Institute, College of Health, Adelaide University, Adelaide, South Australia, Australia.
Tara M CrawfordRobinson Research Institute, College of Health, Adelaide University, Adelaide, South Australia, Australia.
Shem RichardsGoldilocks Suit, Adelaide, South Australia, Australia.
Chad C AndersenRobinson Research Institute, College of Health, Adelaide University, Adelaide, South Australia, Australia.
Michael J StarkRobinson Research Institute, College of Health, Adelaide University, Adelaide, South Australia, Australia.ORCID https://orcid.org/0000-0003-1835-8679

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWearable newborn-monitoring devices are increasingly popular and widely available for home use. One approach includes the use of accelerometer detection of breathing movements. We investigated the accuracy of breathing and apnoea detection by a wearable accelerometer in a simulated environment.

designThis study used simulation as a method to evaluate the performance of a wearable accelerometer-based breathing detection device. A term mannequin fitted with an accelerometer suit wirelessly linked to a mobile app (Goldilocks) was NeoPuff ventilated through a cuffed endotracheal tube. Peak inspiratory pressure (PIP) levels of 5-25 cmH

resultsPIP level affected both apnoea detection (H(4) = 58.9, p < 0.0001) and breathing detection (H(4) = 86.5, p < 0.001) with performance reduced at 5 cmH

conclusionsThe accelerometer displayed pressure-dependent accuracy, increasing with higher PIP, suggesting a minimum pressure threshold is needed for reliable monitoring. App alert times varied greatly, compounding the accuracy of adverse event detection. To determine their true utility, rigorous investigation of neonatal wearable home-monitoring devices is required.

Indexed as

AccelerometryApneaWearable Electronic DevicesEquipment DesignHumansInfant, NewbornManikinsMonitoring, PhysiologicRespirationaccelerometryapnoeainfantmannequinsimulationwearable electronic device

Identifiers

PMID42294843
PMCPMC13480716

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.