Evidence map›Paper›PMID 42314053›Full record

ReviewAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

From Materials to Medical Images: Translating Perovskite-Based X-Ray Detectors Toward Clinical Imaging.

Sibin Wang, Yongrui Yang, Kun Zhang, Xiaojuan Lu, Hong Yin, Yali Qiao, Xiaojia Zheng, Xiao Zhang, Yanlin Song

Abstract readReview
In one paragraph

Review in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sibin WangDepartment of Radiology, the First Medical Center of Chinese PLA General Hospital, Beijing, P.R. China.
Yongrui YangCAS Key Laboratory of Green Printing, Beijing National Laboratory for Molecular Science (BNLMS), Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China.ORCID https://orcid.org/0000-0002-4942-7078
Kun ZhangCAS Key Laboratory of Green Printing, Beijing National Laboratory for Molecular Science (BNLMS), Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China.
Xiaojuan LuSichuan Research Center of New Materials, Institute of Chemical Materials, China Academy of Engineering Physics, Chengdu, P.R. China.
Hong YinMedical Supplies Center of Chinese PLA General Hospital, Beijing, P.R. China.
Yali QiaoCAS Key Laboratory of Green Printing, Beijing National Laboratory for Molecular Science (BNLMS), Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China.ORCID https://orcid.org/0000-0001-9334-1012
Xiaojia ZhengSichuan Research Center of New Materials, Institute of Chemical Materials, China Academy of Engineering Physics, Chengdu, P.R. China.ORCID https://orcid.org/0000-0002-3963-4073
Xiao ZhangDepartment of Radiology, the First Medical Center of Chinese PLA General Hospital, Beijing, P.R. China.
Yanlin SongCAS Key Laboratory of Green Printing, Beijing National Laboratory for Molecular Science (BNLMS), Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China.ORCID https://orcid.org/0000-0002-0267-3917

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As an indispensable part of modern diagnosis and image-guided therapy, medical X-ray imaging requires detector materials that combine low-dose operation, high spatial resolution, fast response, energy-resolved capability, long-term stability, and scalable integration. Metal halide perovskites are promising candidates for high-performance and low-cost X-ray absorbers, because their strong X-ray attenuation, tunable composition, defect tolerance, favorable charge transport, and low-temperature processability enable both direct- and indirect-conversion detector designs. However, clinical translation cannot be assessed only by sensitivity or detection limit. Practical medical detectors must also satisfy requirements in modulation transfer function, noise power spectrum, detective quantum efficiency, lag/ghosting, dynamic range, pixel uniformity, readout compatibility, radiation durability, and safety. These requirements define a key gap between laboratory demonstrations and practical clinical applications. This review examines perovskite-based X-ray detectors from a materials-to-medical-images perspective. Conventional detector materials are first considered as reference platforms for defining clinical imaging requirements. Recent progress in perovskite-based X-ray detectors is then discussed with emphasis on their relevance to clinical imaging. Finally, the key barriers to clinical implementation are analyzed. By linking material properties, detector architectures, imaging metrics, and modality-specific requirements, this review outlines a translation roadmap for perovskite-based X-ray detectors toward future low-dose, high-resolution, and energy-resolved clinical imaging.

Indexed as

Calcium CompoundsDiagnostic ImagingOxidesTitaniumHumansX-RaysCalcium CompoundsOxidesperovskiteTitaniumdirect‐conversion detectorsmedical X‐ray imagingmetal halide perovskiteperovskite scintillatorsphoton‐counting CT

Identifiers

PMID42314053
PMCPMC13336363

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.