ArticleJournal of robotic surgery2026
Adverse events and device malfunctions in robotic thyroidectomy: a decade-long analysis of the MAUDE database.
Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The learning curve of robotic esophagectomy: a systematic review with a proposed training and competency assessment framework.Frontiers in oncology · 2026Pooled it
- Perioperative adverse events and device malfunctions associated with ROSA cranial stereotactic robotic surgery a descriptive analysis of FDA MAUDE reports from 2016 to 2026.Journal of robotic surgery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
Robotic thyroidectomy (RT) has gained increasing patient interest and clinical adoption in recent years. However, device-related adverse events and malfunctions remain poorly characterized. A review of the Manufacturer and User Facility Device Experience (MAUDE) database was conducted using the keyword "robotic thyroidectomy" between January 2016 and December 2025. Eligible reports were manually reviewed and classified by malfunctioning domain, intraoperative management, clinical consequence, procedural outcome, post-event manufacturer evaluation, and reporting timeliness. Thirty-two reports were included, and all events occurred intraoperatively. Adjunct energy device accounted for the majority of reports (68.8%), followed by robotic system (25.0%) and access/interface component (6.3%). The most frequently described event pattern was fragment/breakage. Device/component exchange (56.3%) and fragment retrieval/removal (46.9%) were common management measures. Despite these events, 25 procedures (78.1%) were completed robotically as planned, three (9.4%) were completed under downgraded robotic conditions and only one (3.1%) required open conversion. No severe patient injury was noted. In terms of reporting timeliness, the United States Food and Drug Administration (FDA) received 13 reports (40.6%) over 30 days after the event occurred. Meanwhile, four of the 31 evaluable reports (12.9%) exceeded the manufacturer-to-FDA reporting window of 30 days. Although RT-related MAUDE reports were limited and most events appeared manageable, the associated surgical burden may include workflow disruption, repeated troubleshooting, device exchange, and downgraded robotic continuation. These findings highlight the need for RT-specific risk awareness, balanced patient counseling, operative preparedness, structured troubleshooting pathways and timely, standardized post-market surveillance.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.