Evidence map›Paper›PMID 42346327›Full record

ArticleJournal of eye movement research2026

Conventional Versus Virtual Reality-Based Hess-Lancaster Assessment: Agreement and Repeatability in Ocular Motility Evaluation.

Francisco Javier Povedano-Montero, Álvaro Perales-Serrano, Daniela León Lobo, Rut González-Jiménez, Ricardo Bernárdez-Vilaboa, Juan E Cedrún-Sánchez

Abstract read
In one paragraph

Article in Journal of eye movement research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Francisco Javier Povedano-MonteroOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.ORCID 0000-0001-6715-1047
Álvaro Perales-SerranoOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.ORCID 0009-0007-5517-0997
Daniela León LoboOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.
Rut González-JiménezOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.ORCID 0009-0007-6211-9348
Ricardo Bernárdez-VilaboaOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.ORCID 0000-0002-0998-6430
Juan E Cedrún-SánchezOptometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.ORCID 0000-0002-8359-4224

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe conventional Hess-Lancaster test is widely used to assess ocular misalignment across diagnostic gaze positions, but it relies on subjective responses and manual recording. Virtual reality may provide a more standardized framework for ocular motility assessment.

objectivesTo evaluate the agreement and within-method repeatability of point-by-point deviation measurements obtained with the conventional Hess-Lancaster test and a VR-based Hess-Lancaster assessment implemented in Dicopt Pro.

methodsThis cross-sectional observational study included 52 adults with suspected or diagnosed ocular motility disorders. Participants underwent both assessments using the same predefined gaze positions. Agreement was assessed using Bland-Altman analysis, concordance correlation coefficients, mean absolute differences, and mixed-effects modeling. Repeatability was evaluated in a subset with repeated measurements using session-to-session differences and intraclass correlation coefficients.

resultsThe VR-based assessment showed moderate agreement with the conventional test, with a mean concordance correlation coefficient of 0.57 for both eyes. Mean bias was 1.22 prism diopters for the right eye and 0.10 prism diopters for the left eye. Repeatability estimates were moderate-to-good, with ICC values ranging from 0.62 to 0.83, although repeated measurements were available only in a subset of participants.

conclusionsThe VR-based Hess-Lancaster assessment showed small mean differences and moderate agreement with the conventional test, although both methods should be interpreted within the context of the complete clinical examination.

Indexed as

Bland–Altman analysisDicopt ProHess–Lancaster testocular motilityrepeatabilitystrabismusvirtual reality

Identifiers

PMID42346327
PMCPMC13302422

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.