Evidence map›Paper›PMID 42354745›Full record

ArticleMicromachines2026

High-Precision LCCD-Based Focus Metrology for I-Line Lithography: Multi-Sample Repeatability and Adaptability Evaluation.

Hengrui Guan, Xinxin Zhao, Yuheng Chu, Wuhao Liu, Yongxing Yang, Dapeng Kuang, Maoxin Song, Mingchun Ling, Jin Hong

Abstract read
In one paragraph

Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hengrui GuanGraduate School of Science Island, University of Science and Technology of China, Hefei 230026, China.ORCID 0009-0008-5375-9295
Xinxin ZhaoGraduate School of Science Island, University of Science and Technology of China, Hefei 230026, China.
Yuheng ChuGraduate School of Science Island, University of Science and Technology of China, Hefei 230026, China.
Wuhao LiuGraduate School of Science Island, University of Science and Technology of China, Hefei 230026, China.ORCID 0009-0003-5820-6810
Yongxing YangGraduate School of Science Island, University of Science and Technology of China, Hefei 230026, China.ORCID 0000-0002-0864-9029
Dapeng KuangAnhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China.
Maoxin SongAnhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China.
Mingchun LingAnhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China.
Jin HongAnhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Achieving stable local focus-height measurement across different material surfaces is important for I-line-lithography-related inspection, where sub-micrometer height deviations can affect imaging quality, exposure uniformity, and subsequent autofocus performance. This study evaluates the local focus-height repeatability of a linear charge-coupled device (LCCD)-based focus metrology system under several I-line-lithography-related material-surface conditions. The prototype integrates fiber-coupled LED illumination, telecentric projection and imaging optics, reference marks, and a two-step localization procedure based on template matching and centroid estimation; the dual-wavelength source is treated as part of the fixed optical configuration. Tests were performed on silicon wafers, GaAs bright substrates, sapphire, infrared transmissive material, and SiC, covering different reflectivity levels and surface structures. The measured peak-to-valley repeatability was 35-37 nm for highly reflective samples and 40-54 nm for intermediate- or low-reflectivity and microstructured samples, all below the selected 70 nm conservative engineering criterion derived from the depth-of-focus estimate. These results indicate that the integrated LCCD measurement chain maintained stable local repeatability within the tested material-surface range, providing experimental support for further development of local focus metrology and precision optical inspection.

Indexed as

I-line inspectionLCCD-based focus metrologylocal focus-height measurementmaterial-surface adaptabilityrepeatabilitysemiconductor metrology

Identifiers

PMID42354745
PMCPMC13304349

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.