Evidence map›Paper›PMID 42359556›Full record

ReviewAdvanced healthcare materials2026

Flexible and Self-Powered Wearable Sensors for Tremor Monitoring in Parkinson'S Disease: Recent Advances in Materials and Device Architectures.

Sirinya Ukasi, Sugato Hajra, Hoe Joon Kim, Saichon Sriphan, Satana Pongampai, Thitirat Charoonsuk, Naratip Vittayakorn

Abstract readReview
In one paragraph

Review in Advanced healthcare materials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sirinya UkasiDepartment of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand.
Sugato HajraDepartment of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu, South Korea.
Hoe Joon KimDepartment of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu, South Korea.ORCID https://orcid.org/0000-0003-1180-7830
Saichon SriphanAdvanced Materials Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-5893-6093
Satana PongampaiAdvanced Materials Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand.
Thitirat CharoonsukAdvanced Materials Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-9027-9556
Naratip VittayakornDepartment of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand.

Funding

King Mongkut's Institute of Technology, LadkrabangKing Mongkut's Institute of Technology, Ladkrabang (KMITL) N42A690584Ministry of Science and ICT of Korea RS-2024-00346135Ministry of Science and ICT of Korea RS-2024-00406674Program Management Unit for Frontier Brainpower and Future Industries B39G690074
6 · The paper itself

Abstract

Parkinson's disease (PD) is a progressive neurodegenerative disorder where tremor remains one of the most prominent and disabling motor symptoms. Traditional clinical rating scales for disease severity rely on clinician observation and patient self-report, often failing to capture the dynamic and continuous nature of tremors in daily life. This drives the development of objective monitoring technologies, such as wearable sensors, for more accurate evaluation of PD severity. However, many existing systems use rigid materials that lack the mechanical compliance and skin conformability required for stable biointegration. This review summarizes advances in flexible wearable sensors for PD tremor assessment from material innovations to a device engineering perspective, covering inertial measurement units (IMUs), electromyography (EMG), and emerging self-powered systems such as triboelectric (TENG) and piezoelectric nanogenerators (PENG). This review highlightshow functional materials, microstructural design, and device architectures govern sensing mechanisms and performance, with particular emphasis on the transition from rigid components to soft, skin-interfaced technologies. Recent patent activity reflects a shift toward multimodal, wireless, and clinically integrated platforms. Despite progress, challenges remain, including motion artifacts, durability, and limited large-scale clinical validation. Integration of flexible materials, self-powered designs, and AI-driven analytics enables continuous, personalized monitoring, moving closer to real-world clinical deployment and improved patient care.

Indexed as

Parkinson DiseaseTremorWearable Electronic DevicesDigital HealthElectromyographyEquipment DesignHumansMonitoring, Physiologicflexible sensorsParkinson's diseaseself‐powered systemstremor monitoringwearable devices

Identifiers

PMID42359556
PMCPMC13447966

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.