Evidence map›Paper›PMID 42362477›Full record

ArticleInternational journal of laboratory hematology2026

Rapid Centrifugation for Coagulation Testing: A Multianalyzer Validation Study Harmonizing Preanalytical Protocols for Total Laboratory Automation.

Orakan Limpornpugdee, Jirapa Kaewkhruawan, Pitchayaporn Riyagoon, Waroonkarn Laiklang, Wararat Masalae, Surapat Tanticharoenkarn, Kwanlada Chaiwong, Phongsapak Pipatnavakij, Parinda Limprasert, Chutitorn Ketloy and 1 more

Abstract readValidation Study
In one paragraph

Article in International journal of laboratory hematology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Orakan LimpornpugdeeDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0009-0000-1790-9841
Jirapa KaewkhruawanDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Pitchayaporn RiyagoonDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Waroonkarn LaiklangDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Wararat MasalaeDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Surapat TanticharoenkarnDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Kwanlada ChaiwongDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Phongsapak PipatnavakijDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Parinda LimprasertDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Chutitorn KetloyDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-7043-8062
Eakachai PrompetcharaDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0001-7565-9211

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesCentrifugation requirements differ between coagulation and clinical chemistry testing, potentially limiting workflow efficiency and total laboratory automation (TLA). Coagulation assays typically require standard centrifugation at 1500 g for 15 min, whereas chemistry samples use a rapid protocol at 2300 g for 5 min. This study evaluated the impact of rapid centrifugation on prothrombin time (PT), activated partial thromboplastin time (APTT), and D-dimer results.

methodsBlood samples were prospectively collected from volunteers in 3, 2, and pediatric 1 mL citrate tubes and were processed using standard or rapid centrifugation. Testing was performed for PT, APTT, and D-Dimer on Sysmex CN3000 and ACL-TOP 750 analyzers, with residual platelet counts assessed.

resultsA total of 130 samples were analyzed (41 from 3 mL tubes, 41 from 2 mL tubes, and 39 from 1 mL tubes). Rapid centrifugation produced significantly higher residual platelet counts than the standard protocol (39.2 × 10

conclusionsRapid centrifugation at 2300 g for 5 min provides coagulation results comparable to the standard protocol and may facilitate integration of coagulation testing into TLA workflows.

Indexed as

Automation, LaboratoryBlood CoagulationBlood Coagulation TestsCentrifugationFibrin Fibrinogen Degradation ProductsHumansPartial Thromboplastin TimePlatelet CountProthrombin TimeFibrin Fibrinogen Degradation Productsfibrin fragment Dcentrifugationcoagulation assayspreanalytictotal lab automation

Identifiers

PMID42362477
PMCPMC13555175

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.