Evidence map›Paper›PMID 42374358›Full record

ArticleBMC musculoskeletal disorders2026

Biomechanical evaluation of a novel cervical interfacet self-locking cage versus ACDF: a goat cadaveric study combined with human CT-based finite element analysis.

Junwei Zhang, Xiaolei Sheng, Kexin Chen, Zhi Xu, Haitao Lu, Shuo Feng, Maji Sun, Feng Yuan

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Junwei Zhang *Department of Orthopedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.
Xiaolei Sheng *Department of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University, Zhangjiagang, 215600, China.
Kexin Chen *Department of Orthopedics, Xuzhou City Hospital of Traditional Chinese Medicine, Xuzhou, 221000, China.
Zhi XuDepartment of Orthopedics, Zhangjiagang fifth People's Hospital, Zhangjiagang, 215600, China.
Haitao LuDepartment of Orthopedics, Nanjing Lishui People's Hospital, Nanjing, 210000, China.
Shuo FengDepartment of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.
Maji SunDepartment of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China. 376333460@qq.com.
Feng YuanDepartment of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China. xzmuyf@163.com.

Funding

Science and Technology Project of Jiangsu Provincial Health Commission ZD2022064
6 · The paper itself

Abstract

backgroundAnterior cervical discectomy and fusion (ACDF) is a well-established treatment for cervical degenerative disease (CDD). Nevertheless, its anterior approach carries inherent risks to critical neck structures, prompting the exploration of posterior fusion alternatives for selected patients. Traditional anterior cervical discectomy and fusion (ACDF) for cervical degenerative disease involves navigating complex anterior neck anatomy with potential risks to critical neurovascular structures, motivating the development of safer posterior fusion alternatives.

methodsTwenty-four fresh C5-C6 segments from adult goats were randomly assigned to the intact, ACDF, and CILC groups (n = 8 per group). After confirming the anatomical similarity between goat and human cervical spines via three-dimensional reconstruction, corresponding surgical procedures were performed at the C5-C6 level. Range of motions (ROMs) in flexion-extension, lateral bending, and axial rotation were measured under a pure moment of 1.5 N·m using a material testing machine. A finite element model of C3-C7 was developed based on computed tomography data from healthy adults. ACDF and CILC procedures were simulated, with a 1 N·m moment and 73.6 N pre-load applied to analyse the stress distribution in adjacent segment discs, facet cartilage, and implants.

resultsAnatomical measurements confirmed a high similarity between goat and human C5-C6 segments (P > 0.05), validating its use as an experimental model. In biomechanical tests, both CILC and ACDF significantly reduced segmental motion (P < 0.001). Compared with ACDF, CILC demonstrated greater ROM in flexion (3.31° vs. 1.52°, P < 0.05), but superior stability in extension (1.86° vs. 3.86°) and axial rotation (left: 5.89° vs. 8.19°; right: 6.11° vs. 8.89°) (P < 0.05). Finite element analysis confirmed model reliability, demonstrating close alignment between predicted and reported ROM values. CILC generated lower or comparable stress in C3/4 and C4/5 discs compared with ACDF, but higher stress at C5/6. Moreover, CILC resulted in higher facet joint contact forces and implant stress than ACDF, particularly during flexion and extension.

conclusionAlthough CILC demonstrates biomechanical performance comparable to ACDF with specific advantages in controlling extension and axial rotation without significant advantages, its posterior minimally invasive approach effectively avoids neurovascular risks associated with anterior surgery. The device provides a safer alternative for cervical fusion, particularly in cases with complex anterior anatomy or those requiring revision surgery. However, the observed higher facet and implant stresses underscore the need for careful patient selection, particularly regarding pre-existing facet joint condition and bone quality.

Indexed as

Cervical VertebraeDiskectomyFinite Element AnalysisSpinal FusionTomography, X-Ray ComputedAnimalsBiomechanical PhenomenaCadaverFemaleGoatsHumansRange of Motion, ArticularAdjacent segment diseaseAnterior cervical discectomy and fusionBiomechanicsCervical degenerative diseaseCervical interfacet self-locking cage (CILC)

Identifiers

PMID42374358
PMCPMC13471593

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.