Evidence map›Paper›PMID 42377361›Full record

ArticleOrthopaedic surgery2026

The Effect of the Coronal Alignment of Extension Stem on Component Displacement and Stress During Total Knee Arthroplasty: A Finite Element Study.

Lingce Kong, Xingkai Wang, Huijun Kang, Zhenhui Huo, Ming Li, Fei Wang, Wei Lin

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lingce KongDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Xingkai WangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Huijun KangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Zhenhui HuoDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Ming LiDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Fei WangDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.
Wei LinDepartment of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, China.

Funding

Basic Discipline Strengthening Program of Hebei Medical University Third Hospital ydsyqjjh202501Hebei Province Higher Education Institution Scientific Research Project CXZX2025004Key R&D Program of Hebei Province 2331817DNational Key Research and Development Program of China 2023YFB4606700
6 · The paper itself

Abstract

objectiveThe biomechanical interaction between coronal alignment and short extension stem use in total knee arthroplasty (TKA) remains insufficiently understood, particularly regarding the balance between tibial component stability and stress shielding. This study aims to investigate the effects of varying bone cut angles on the tibial side and the use of a short extension stem on tibial component displacement and stress distribution. Additionally, it will examine the stresses experienced by both cortical and cancellous bone during primary TKA, employing three-dimensional finite element analysis and elucidating the biomechanical effects of combining kinematic alignment (KA) with a short extension stem in TKA.

methodsA healthy adult female volunteer was selected to create a tibial model of the left knee joint utilizing three-dimensional reconstruction and finite element analysis software. Six finite element models were developed based on a standard tibial plateau prosthesis and a tibial prosthesis with a 30 mm short extension stem. These models were categorized according to mechanical alignment (MA), KA, and a 3° valgus alignment. The simulations were designed to replicate the loads and constraints experienced during weight-bearing activities of the lower limb. Subsequently, we analyzed the displacement and stress distribution of the tibial prosthesis and examined the stress distribution within both the tibial cortical bone and cancellous bone.

resultIn the KA model, there was a notable increase in displacement, an elevation in mean cortical bone Von Mises stress, and a reduction in mean component Von Mises stress when compared to both the MA and the 3° valgus alignment model. The design of the short extension stem effectively decreased the displacement of the prosthesis but led to increased stress on the prosthesis itself. Additionally, this design led to a reduction in stress on the cortical bone, suggesting a more pronounced stress-shielding effect.

conclusionThe application of KA in TKA will increase prosthetic displacement and reduce the stress-shielding effect, while the application of short extension stem will reduce prosthetic displacement and increase the stress-shielding effect. The combination of the KA and short extension stem may play a complementary role, but this needs further research to confirm.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisAdultBiomechanical PhenomenaFemaleFinite Element AnalysisHumansImaging, Three-DimensionalProsthesis DesignStress, MechanicalTibiaWeight-Bearingfinite element analysiskinematic alignmentmechanical alignmentshort extension stemtotal knee arthroplasty

Identifiers

PMID42377361
PMCPMC13398614

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.