Evidence map›Paper›PMID 42377494›Full record

ArticleAesthetic plastic surgery2026

Computational Modelling of Platysma Muscle Mechanics: Challenging the Isometric Contraction Paradigm and Implications for the Treatment of Neck Bands.

Eqram Rahman, Parinitha Rao, Alain Michon, Sotirios Ioannidis, Patricia E Garcia, Karim Sayed, Rui Avelar, William Richard Webb, Jean D A Carruthers, Woffles T L Wu

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Aesthetic plastic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Eqram RahmanResearch and Innovation Hub, Innovation Aesthetics, London, UK. Eqram.rahman@gmail.com.ORCID http://orcid.org/0000-0002-8443-8338
Parinitha RaoThe Skin Address, Aesthetic Dermatology Practice, Bangalore, India.
Alain MichonThe Ottawa Skin Clinic/Project Skin MD Ottawa, Ottawa, ON, Canada.
Sotirios IoannidisPlastic Surgery Clinic, 546 21, Thessaloniki, Greece.
Patricia E GarciaPrivate practice in dermatology, Puerto Vallarta, Mexico.
Karim SayedNomi Oslo, Oslo, Norway.
Rui AvelarEvolus, Inc., Newport Beach, CA, USA.
William Richard WebbResearch and Innovation Hub, Innovation Aesthetics, London, UK.
Jean D A CarruthersDepartment of Ophthalmology, University of British Columbia, Vancouver, BC, Canada.
Woffles T L WuWoffles Wu Aesthetic Surgery and Laser Centre 1, Camden Medical Centre, Orchard Boulevard Suite 09-02, Singapore, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPlatysmal bands are among the most visible signs of cervical ageing, commonly attributed to focal isometric contraction zones requiring targeted chemodenervation. However, this paradigm is based primarily on indirect imaging and clinical observation, with limited biomechanical validation.

objectivesTo develop a finite element model of platysma contraction incorporating realistic tissue mechanics and to test whether uniform shortening with fascial tethering alone can reproduce contour deformations classically ascribed to isometric contraction.

methodsA high-resolution finite element framework was created using Abaqus/CAE to simulate a layered cervical composite comprising platysma, superficial fascia, and dermis. Geometries were parametrically defined and varied across a synthetic cohort of 1000 virtual anatomies using Latin hypercube sampling. Constitutive formulations included transversely isotropic hyperelastic muscle, viscoelastic fascia with Prony series relaxation, and nonlinear dermis. Simulations varied contraction amplitude (5-15%) and tether density (0-50%). Outputs included cranio-caudal displacement, regional thickness deformation, strain energy, and divergence. Supplementary sustained contraction simulations assessed viscoelastic creep over 300 s.

resultsUniform contraction combined with variable fascial tethering reproduced localized thickening and restricted gliding without requiring isometric contraction zones. Maximal midline thickness increased proportionally with tether density (0.17 mm at 0% tethering to 0.65 mm at 50%), and displacement divergence amplified radial contour deformation. Sensitivity analysis confirmed robustness to ±20% variations in tissue stiffness. Viscoelastic creep simulations suggested progressive strain accumulation (+7% midline thickness over 5 minutes).

conclusionsThese findings suggest that platysmal bands can emerge from predictable passive deformation driven by uniform shortening over heterogeneous anchoring, challenging conventional models of focal hyperactivity. This framework supports the hypothesis that distributed injection protocols targeting tension gradients rather than only visually prominent bands may warrant investigation and highlights the need for further clinical validation of simulation-informed strategies. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Indexed as

Computer SimulationIsometric ContractionSkin AgingSuperficial Musculoaponeurotic SystemBiomechanical PhenomenaFinite Element AnalysisHumansBiomechanicsBotulinum toxin ACervical contourFascial tetheringFinite element modellingNeck rejuvenationPlatysmal bandSimulation

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.