Evidence map›Paper›PMID 42390693›Full record

Observational studyEuropean journal of pediatrics2026

Ultrasound-guided midline catheters in the neonatal intensive care unit: a single-center pilot study.

Lorenzo Zanetto, Andrea Zamunaro, Daniel Nardo, Antuan Divisic, Fiammetta Della Torre, Sabrina Salvadori, Eugenio Baraldi, Luca Bonadies

Abstract readObservational Study
In one paragraph

Observational study in European journal of pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lorenzo ZanettoDepartment of Women's and Children's Health, University of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Andrea ZamunaroDepartment of Women's and Children's Health, University of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Daniel NardoNeonatal Intensive Care Unit, Department of Women's and Children's Health, University Hospital of Padova, via Giustiniani, 2, 35128, Padova, Italy.
Antuan DivisicPediatric Palliative Care - Pain Service, Department of Women's and Children's Health, University Hospital of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Fiammetta Della TorreDepartment of Women's and Children's Health, University of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Sabrina SalvadoriNeonatal Intensive Care Unit, Department of Women's and Children's Health, University Hospital of Padova, via Giustiniani, 2, 35128, Padova, Italy.
Eugenio BaraldiDepartment of Women's and Children's Health, University of Padova, Via Giustiniani 2, 35128, Padova, Italy.
Luca BonadiesDepartment of Women's and Children's Health, University of Padova, Via Giustiniani 2, 35128, Padova, Italy. luca.bonadies@unipd.it.ORCID https://orcid.org/0000-0001-7700-3056

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To assess the feasibility and performance of ultrasound-guided midline catheters in term and preterm neonates requiring prolonged intravenous therapy without an indication for central access, and to generate hypotheses on factors influencing catheter outcomes. Single-center prospective observational cohort: 70 consecutive neonates received 2-Fr polyurethane midline catheters in a level IV NICU (March 2024-November 2025). Data were analyzed descriptively; complication-free survival was estimated by Kaplan-Meier, and exploratory subgroup comparisons used Fisher's exact test. Mean weight at insertion was 2582 g (range 700-4920), including very low-birth-weight infants. Median dwell time was 9 days (range 0-176), corresponding to 1144 catheter-days. The primary composite outcome (complication-free dwell ≥ 7 days or elective removal before day 7) was met in 94.3% of devices. Kaplan-Meier complication-free survival was 98.6% at 3 days and 81.2% at 14 days. Device-related complications occurred in 21.4%, predominantly minor and resolving after removal. Bloodstream infection and thrombosis rates were 2.62 and 0.87 per 1000 catheter-days; no thrombophlebitis occurred. Complication rates did not differ by vein diameter < 2 mm or weight < 1500 g, although the study was underpowered for these comparisons.

conclusionIn this pilot study, ultrasound-guided midline catheters were feasible in neonates, including very low-birth-weight infants and those with small-caliber veins, with predominantly minor complications. These hypothesis-generating findings require confirmation in adequately powered; comparative studies before midlines can be recommended as an alternative to central access or repeated peripheral cannulation. WHAT IS KNOWN: • Midline catheters may offer an intermediate option between peripheral and central venous access, but neonatal experience, particularly in preterm infants, is limited. • Data on the feasibility and performance of midline catheters in the NICU are scarce. WHAT IS NEW: • In this single-center pilot cohort of 70 neonates, ultrasound-guided midline catheters achieved a high rate of complication-free dwell time, with predominantly minor, self-limiting complications. • Complication rates did not appear to increase in infants < 1500 g or with veins < 2 mm; these hypothesis-generating observations require confirmation in adequately powered studies.

Indexed as

Catheterization, Central VenousCatheters, IndwellingUltrasonography, InterventionalCatheter-Related InfectionsFeasibility StudiesFemaleHumansInfant, NewbornInfant, PrematureIntensive Care Units, NeonatalMalePilot ProjectsProspective Studies

Identifiers

PMID42390693
PMCPMC13328151

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.