Evidence map›Paper›PMID 42451307›Full record

ArticleSensors (Basel, Switzerland)2026

IoT-Based Isolation Ward Monitoring System Prototype.

Mohamed A Torad, Ahmed A M Torad, Mona Mohamed Taha, Eslam Samy El-Mokadem

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohamed A ToradDepartment of Electronics and Communication Engineering, Higher Technological Institute (HTI), 10th of Ramadan City 44634, Egypt.ORCID 0000-0001-8621-4410
Ahmed A M ToradDepartment of Physical Therapy and Health Rehabilitation, Jouf University, Sakaka 72341, Saudi Arabia.ORCID 0000-0003-4170-6694
Mona Mohamed TahaDepartment of Rehabilitation Sciences, College of Health and Rehabilitation Sciences, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.ORCID 0000-0001-9080-5061
Eslam Samy El-MokademDepartment of Electronics and Communication Engineering, Higher Technological Institute (HTI), 10th of Ramadan City 44634, Egypt.ORCID 0000-0002-9390-5524

Funding

Princess Nourah bint Abdulrahman University PNURSP2026R209
6 · The paper itself

Abstract

The COVID-19 pandemic exposed critical vulnerabilities in healthcare systems worldwide, placing healthcare workers (HCWs) at severe infection risk through direct patient contact. Epidemiological data confirm that HCWs were approximately seven times more likely to develop severe COVID-19 than other occupations, with over 7000 HCW deaths recorded globally by mid-2020. This paper presents the design and laboratory proof-of-concept validation of an IoT-based remote patient-monitoring system prototype-the IoT-Based Isolation Ward Monitoring System Prototype-designed to eliminate unnecessary patient-to-HCW physical contact while maintaining continuous, real-time physiological surveillance. The system integrates multi-sensor hardware comprising an AD8232 ECG module, a MAX30100 pulse oximeter, an NTC thermistor, and an MQ-135 CO2 sensor. These sensors interface with an Arduino UNO for data acquisition, while localized edge computing is executed on a Raspberry Pi 3B. A convolutional neural network (CNN) trained on the MIT-BIH Arrhythmia Database classifies heartbeats into five distinct categories. By utilizing SMOTE resampling on 109,446 samples, the network achieves an on-device inference latency of under 200 ms. The sensor data are transmitted to a Firebase Realtime Database via an authenticated REST API, which synchronizes data across dual front-end interfaces: a LabVIEW desktop dashboard for clinical oversight and a cross-platform Flutter mobile application for mobile monitoring. End-to-end technical validation under controlled laboratory conditions confirmed round-trip cloud latencies between 300 and 800 ms, error-free threshold alert generation, and sub-second latency for the integrated chat utility. The proposed system uniquely combines hardware sensing, ML-based ECG classification, cloud storage, a LabVIEW physician dashboard, and bidirectional doctor-patient mobile communication into a single unified, low-cost platform.

Indexed as

Internet of ThingsConvolutional Neural NetworksCOVID-19Dashboard SystemsDigital HealthElectrocardiographyHumansMonitoring, PhysiologicOximetryPandemicsRemote Patient MonitoringSARS-CoV-2convolutional neural networkCOVID-19ECG classificationfirebaseFlutterInternet of Things (IoT)LabVIEWMITDBRaspberry Piremote patient monitoringvital signs

Identifiers

PMID42451307
PMCPMC13364453

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.