Evidence mapPaperPMID 42452829Full record

ArticleCurrent medical imaging2026

Association of Carotid Plaque Gray-scale Median with Plaque Size and Degree of Stenosis.

Salahaden R Sultan

Abstract read
In one paragraph

Article in Current medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Salahaden R SultanDepartment of Radiologic Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia.ORCID 0000-0001-9981-6138

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAtherosclerosis remains a leading cause of Cardiovascular Disease (CVD) mortality and morbidity. Ultrasound Gray-Scale Median (GSM) of carotid plaques and plaque size have shown potential as markers of vulnerability and predictors of cerebrovascular events. This prospective study investigated the correlation between carotid plaque size, Degree of Stenosis (DoS), and GSM. MATERIALS AND

methodsIn this study, 32 patients with 43 carotid plaques identified by B-mode ultrasound were recruited. Each B-mode ultrasound image was normalized, and the GSM of carotid plaque echogenicity was quantified using the histogram feature in Adobe Photoshop. GSM data from the thickest plaque area were obtained, and plaque length, thickness, area, and DoS were measured using ImageJ software. Correlations between plaque size, DoS, and GSM were identified and assessed using Spearman's correlation coefficient.

resultsSignificant negative correlations were observed between carotid plaque GSM and plaque size (plaque length, r = -0.34, p = 0.02; plaque thickness, r = -0.30, p = 0.04; plaque area, r = -0.40, p = 0.008), with a trend toward significant negative correlation with DoS (r = -0.26, p = 0.08). DISCUSSION: This study identifies an inverse relationship between carotid plaque GSM and plaque size parameters, indicating that hypoechoic plaques, characterized by lower GSM values, are generally larger and potentially more vulnerable to rupture. These findings emphasize the importance of combining structural metrics, such as plaque size and degree of stenosis, with compositional evaluation and their echogenicity for comprehensive cerebrovascular risk assessment. Hypoechoic plaques often correspond to lipid-rich, inflamed lesions with thin fibrous caps, which are histological features associated with an increased risk of cerebrovascular events. The demonstrated associations underscore the clinical relevance of GSM as a noninvasive surrogate biomarker that reflects both local plaque vulnerability and the broader systemic burden of atherosclerosis. Thus, the B-mode ultrasound-derived GSM is a practical and informative tool for enhancing risk stratification and guiding management strategies in patients with carotid artery disease.

conclusionOur findings reveal significant negative correlations between carotid GSM and plaque size parameters, with a nonsignificant trend for DoS. These findings suggest that hypoechoic plaques, characterized by lower GSM values, are generally larger in size and potentially more vulnerable. Future large-scale longitudinal studies with repeated evaluations are required to validate these findings.

Indexed as

Carotid StenosisPlaque, AtheroscleroticUltrasonography, Carotid ArteriesAgedFemaleHumansMaleMiddle AgedProspective StudiesSeverity of Illness IndexUltrasonographyAtherosclerosisB-modeCarotid plaqueEchogenicityGray-scale medianUltrasound

Identifiers

PMID42452829
PMCPMC13463222

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked