ArticleCureus2026
Assessing Facial Skin Hydration via Tissue Dielectric Constant (TDC): Suitability of Single Versus Multiple Measurements.
Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNoninvasive tissue dielectric constant (TDC) measurements provide a useful index of local skin water because TDC, measured at 300 MHz, depends directly on the amount of free and bound water in the measurement volume. Since the hydration status of facial skin is a fundamental factor affecting multiple dermatological conditions, including rosacea, psoriasis, and eczema, TDC values may be useful for assessing dermal hydration in these conditions. Although some data on female facial values have been reported, data on male facial TDC are quite limited. Further, since multiple skin sites often need to be evaluated, time constraints in the clinic may limit the acquisition of useful data if multiple measurements are required at each site. Thus, the study's goal was to determine if a single TDC measurement, rather than averaging multiple measurements, would be sufficient. Methods: TDC was measured in triplicate bilaterally at the forehead (F), cheek (C), and jowl (J) areas to an effective depth of 1.5 mm in 40 male subjects while they were supine and then seated after 15 minutes at each position. The first TDC value (TDC1) was compared with the average of the first and second (TDC12) and with the triplicate average (TDC123).
resultsGroup-average TDC values did not differ statistically among TDC1, TDC12, and TDC123 at any facial site, whether measured with the subject supine or seated. Supine TDC1 values (mean ± SD) for the F, C, and J areas were 42.11 ± 3.19, 39.15 ± 5.49, and 43.44 ± 4.56, respectively. The corresponding TDC values with subjects seated were 40.68 ± 2.99, 38.49 ± 5.54, and 41.97 ± 4.37. Supine-seated differences were statistically significant at the forehead and jowl areas (p < 0.001) but not at the C (p = 0.193). TDC differences among sites, though small, were statistically significant (p < 0.001) at both positions. C had the lowest TDC value. On an individual basis, no subject had a TDC1 value that differed by more than 3% from the triplicate average.
conclusionsResults indicate that when clinical time is a concern, or when experimental time needs to be shortened for any reason, accurate facial TDC data may be obtained at the F, C, and J areas using a single TDC measurement with the subject either supine or sitting, whichever is appropriate for the patient and examiner.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.