ArticleAnalytical and bioanalytical chemistry2026
Validated SPE-HPLC-MS/MS analysis of steroid hormones in H295R cell culture medium: chromatographic separation and ESI response in the presence of potential endocrine-disrupting chemicals.
Article in Analytical and bioanalytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A sensitive and robust SPE-HPLC-MS/MS method was developed and validated for the simultaneous quantification of five steroid hormones in H295R cell culture medium. Chromatographic separation of the target steroids and selected potential endocrine‑disrupting chemicals (EDCs) was achieved using a ZORBAX Eclipse Plus C18 column (1.8 µm, 95 Å, 50 × 2.1 mm). Sample preparation was performed by solid‑phase extraction employing hydrophilic-lipophilic balanced polymeric reversed‑phase sorbent cartridges. Extraction recovery was evaluated at three concentration levels, tailored to each steroid, and exceeded 80% for all analytes. Intra‑ and inter‑day precision, expressed as relative standard deviation (RSD), ranged from 1 to 12%. Method limits of quantification were in the range of 8 and 73 pg mL⁻
Indexed as
Identifiers
42496707What Socratic holds
Registered trials