Body surface potential driven personalisation of electrophysiological digital twins in hypertrophic cardiomyopathy.
Article in PLoS computational biology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
backgroundHypertrophic cardiomyopathy (HCM) is associated with marked inter-patient heterogeneity in ventricular electrophysiology, contributing to arrhythmic risk that is insufficiently captured by current clinical methods. Electrocardiographic imaging (ECGI) provides high-density body surface potential (BSP) measurements but remains largely descriptive. Computational modelling offers a mechanistic framework to interpret BSP signals in terms of underlying tissue-level properties. METHODS AND
findingsWe developed a BSP-driven workflow to construct patient-specific electrophysiology (EP) models of HCM by integrating multimodal clinical imaging with Bayesian model calibration. Anatomically detailed torso-heart finite-element models were generated for 17 HCM patients using thoracic computed tomography (CT), cardiac magnetic resonance imaging (CMR), and 252-electrode BSP recordings. Ventricular depolarisation and repolarisation were simulated using a reaction-eikonal (RE) formulation coupled to a biophysically detailed ToR-ORd-dynCl ionic model. Emulator-based Bayesian history matching (HM) was used to personalise EP parameters, with staged calibration of QRS and T-wave morphology informed by targeted sensitivity analysis. The calibrated cohort reproduced clinical BSP morphology with Pearson correlation coefficient (PCC) [Formula: see text] for a median of 94.0% (IQR: 91.6 to 96.8%) of electrodes, achieving a median PCC of 0.89 (IQR: 0.80 to 0.94) across the full 252-electrode vest. Calibration substantially reduced uncertainty in the high-dimensional EP parameter space while yielding physiologically plausible conduction and repolarisation properties. Models calibrated exclusively to sinus rhythm robustly generalised to right-ventricular (RV) apical pacing without parameter retuning, reproducing clinically observed pacing-induced trends in depolarisation and repolarisation. Exploratory analysis revealed biologically consistent associations between inferred EP parameters and patient demographics.
conclusionsThis study demonstrates that high-density BSP data can be used to functionally personalise mechanistic EP in HCM. The framework captures intrinsic patient-specific EP properties and generalises beyond the calibration condition, supporting its use for mechanistic investigation of arrhythmogenic substrate.