Evidence map›Paper›PMID 42510399›Full record

ArticleBioengineering (Basel, Switzerland)2026

Millimeter-Wave Radar-Based ECG Reconstruction Using Respiratory Harmonic Suppression and CA-WTBNet.

Bowen Xiao, Chuyi Zhou, Lu Wang, Caiping Song, Yong Jia

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bowen XiaoSchool of Mechanical and Electrical Engineering, Chengdu University of Technology, Chengdu 610059, China.ORCID 0009-0001-1912-8018
Chuyi ZhouSchool of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.
Lu WangSchool of Mechanical and Electrical Engineering, Chengdu University of Technology, Chengdu 610059, China.
Caiping SongSchool of Mechanical and Electrical Engineering, Chengdu University of Technology, Chengdu 610059, China.
Yong JiaSchool of Mechanical and Electrical Engineering, Chengdu University of Technology, Chengdu 610059, China.ORCID 0000-0003-3165-3349

Funding

Chengdu University of Technology 2025AI019Science and Technology Department of Sichuan Province 2024YFFK0417、24NSFSC0498
6 · The paper itself

Abstract

Millimeter-wave radar enables non-contact monitoring of cardiac activity and therefore has the potential to reconstruct electrocardiogram signals without surface electrodes. However, existing radar-based electrocardiogram reconstruction methods still suffer from incomplete extraction of heartbeat-related information and insufficient modeling of electrocardiogram-related features, which limits reconstruction accuracy. To address these issues, this study proposes a millimeter-wave radar-based electrocardiogram reconstruction method that integrates a respiratory-harmonic-suppressed multi-channel signal-processing frontend with the proposed CA-WTBNet deep reconstruction network. First, based on maximal overlap discrete wavelet transform-based multi-resolution analysis, respiratory harmonics mixed into heartbeat-related components are suppressed by combining respiratory harmonic detection with a heart-rate frequency protection strategy, while cardiac-related information is preserved as much as possible. A multi-channel input representation is then constructed. Meanwhile, the proposed deep reconstruction network is developed to jointly model complementary channel-wise features, local waveform morphology, and temporal dependencies by integrating channel-attention mechanisms, convolutional residual modules, window-based Transformer blocks, and bidirectional long short-term memory. Experiments conducted on the public dataset show that our method achieves an average Pearson correlation coefficient of 0.9641, a mean normalized root mean square error of 0.0458, an average R-peak F1 score of 0.9956, and an average R-peak timing error of 3.13 ms on the test set. In comparison with related studies on the same public Resting dataset, the proposed method achieves the best overall performance among the compared methods, with a 0.53% improvement in Pearson correlation coefficient and a 10.20% reduction in normalized root mean square error over the best-performing compared method.

Indexed as

bidirectional long short-term memorydeep learningelectrocardiogram reconstructionmaximal overlap discrete wavelet transformmillimeter-wave radarnon-contact cardiac monitoringrespiratory harmonic suppressionR-peak detectionvital signs

Identifiers

PMID42510399
PMCPMC13405996

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.