Evidence mapPaperPMID 42510490Full record

ArticleBioengineering (Basel, Switzerland)2026

Computational Assessment of Electrical and Thermal Effects of Epicardial Pulsed Field Ablation Adjacent to Stented Arteries.

Francisco Estevez-Laborí, Maite Izquierdo, Ken Coffey, Barry O'Brien, Ana González-Suárez

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Francisco Estevez-LaboríBioMIT, Department of Electronic Engineering, Universitat Politècnica de València, Building 7F, Camino de Vera, s/n, 46022 Valencia, Spain.
Maite IzquierdoElectrophysiology Unit, Cardiology Department, Hospital Universitario y Politécnico La Fe de Valencia, 46026 Valencia, Spain.
Ken CoffeyAtriAN Medical Ltd., Unit 204, University of Galway Business Innovation Centre, Upper Newcastle, H91 W60E Galway, Ireland.
Barry O'BrienAtriAN Medical Ltd., Unit 204, University of Galway Business Innovation Centre, Upper Newcastle, H91 W60E Galway, Ireland.
Ana González-SuárezBioMIT, Department of Electronic Engineering, Universitat Politècnica de València, Building 7F, Camino de Vera, s/n, 46022 Valencia, Spain.ORCID 0000-0002-1813-4176

Funding

Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional PID2022-136273OA-C33Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional PID2022-136273OB-C31Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional RYC2022-036965-I
6 · The paper itself

Abstract

backgroundCurrent ablation strategies for the treatment of cardiac arrhythmias remain suboptimal. Treating cardiac arrhythmias using epicardial pulsed field ablation (PFA) selectively targets ganglionated plexi (GPs) within epicardial fat, offering a promising alternative to thermal ablation. Previous computational studies lacked physiological realism, excluding catheter geometry, fluid flow and post-PFA thermal latency. This study aimed to develop a realistic 3D epicardial PFA model integrating a clinical catheter, clinical PFA parameters and a sequentially coupled electro-thermal-fluid dynamics model, including thermal latency, to assess electrical and thermal collateral effects near stented coronary arteries.

methodsThe model included epicardial fat, myocardium, blood, and the left circumflex artery containing a metallic stent positioned 0.25 mm beneath the catheter electrodes. Pulses of 1000, 2000, and 2500 V (60 pulses × 100 µs, 1 Hz) were simulated to analyze electric field distribution, PFA-induced lesion volume, temperature evolution, and Arrhenius-based thermal damage, including a 90 s post-pulse period to account for thermal latency. The PFA-threshold of 1000 V/cm was considered.

resultsThe artery reduced PFA-induced lesion size mainly by occupying fat tissue volume, while the stent shielded the lumen without altering fat lesion volume. The presence of a stent produced localized electric field enhancement at the arterial wall, with up to 3.83% of the arterial wall volume affected by PFA in the worst-case configuration. At clinical settings (1000 V), temperature remained below 40 °C and no collateral damage occurred. Voltages > 2000 V increased arterial wall heating, with thermal damage expanding up to five-fold during latency in the epicardial fat. Myocardium remained unaffected in all cases.

conclusionsThe computational model developed in this study indicates that clinically relevant PFA parameters (1000 V) produce localized electric field enhancement at the stent-artery interface, resulting in limited collateral electrical effects in the arterial wall, while avoiding collateral thermal effects and preserving the myocardium. However, the use of higher pulse voltages can lead to delayed thermal damage within the epicardial fat.

Indexed as

computer modelingcoronary arterymetal stentpulsed field ablationthermal-side effects

Identifiers

PMID42510490
PMCPMC13404282

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked