Evidence map›Paper›PMID 42510504›Full record

ReviewBioengineering (Basel, Switzerland)2026

From Modified Haller Index to a Novel Patented Anatomical Measurement Device: Engineering Development, Validation, and Clinical Applications of Non-Invasive Thoracic Morphometry.

Andrea Sonaglioni, Gian Luigi Nicolosi, Massimo Baravelli, Michele Lombardo

Abstract readReview
In one paragraph

Review in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andrea SonaglioniDivision of Cardiology, IRCCS MultiMedica, 20123 Milan, Italy.ORCID 0000-0001-7641-8831
Gian Luigi NicolosiDivision of Cardiology, Policlinico San Giorgio, 33170 Pordenone, Italy.ORCID 0000-0002-2218-2808
Massimo BaravelliDivision of Cardiology, IRCCS MultiMedica, 20123 Milan, Italy.
Michele LombardoDivision of Cardiology, IRCCS MultiMedica, 20123 Milan, Italy.

Funding

Ministero della Salute CUP: I43C25000300001
6 · The paper itself

Abstract

Thoracic morphology is increasingly recognized as an important determinant of cardiopulmonary phenotype, influencing cardiovascular mechanics, respiratory physiology, and the interpretation of diagnostic imaging findings. Although the radiological Haller Index (HI) remains the reference standard for quantifying pectus excavatum severity, its dependence on computed tomography and ionizing radiation limits widespread clinical implementation, particularly in settings requiring serial evaluations. To overcome these limitations, the Modified Haller Index (MHI) was developed as a simple, non-invasive, radiation-free alternative that combines external thoracic anthropometry with echocardiographic assessment. Since its introduction, the MHI has undergone clinical validation and has progressively expanded beyond the assessment of chest wall deformities, demonstrating that thoracic conformation is not merely an anatomical characteristic but a clinically relevant determinant of cardiovascular and respiratory physiology. Growing evidence indicates that thoracic morphology influences cardiac chamber geometry, ventricular filling, stroke volume, myocardial deformation, ventricular-arterial coupling, exercise stress echocardiography findings, pulmonary function, and symptom perception across a broad spectrum of cardiovascular and respiratory diseases. Elevated MHI values identify individuals with a reduced antero-posterior thoracic diameter and a distinctive cardiopulmonary phenotype characterized by external cardiac compression, smaller cardiac chambers, restrictive ventilatory physiology, and apparent alterations in myocardial mechanics despite the absence of intrinsic myocardial disease. Building upon the clinical validation of the MHI, a novel patented anatomical measurement device was engineered to standardize thoracic morphometric assessment by enabling direct acquisition of both latero-lateral and antero-posterior thoracic diameters within a single measurement procedure. The device integrates dedicated anatomical reference elements, an innovative adjustable sternal pointer, movable measurement components, and a standardized acquisition workflow into a portable, low-cost, and radiation-free platform, thereby improving measurement reproducibility while simplifying bedside MHI determination. This narrative review summarizes the historical evolution of thoracic morphometry, the development and clinical validation of the MHI, the engineering rationale, structural architecture, and measurement workflow of the patented device, and the growing evidence supporting the clinical significance of thoracic conformation across cardiovascular and respiratory medicine. Together, the MHI and the proposed anatomical measurement device establish a practical platform for standardized, radiation-free thoracic morphometry that may facilitate routine bedside phenotyping. Future integration with digital technologies, artificial intelligence, and advanced imaging systems may further enable next-generation digital thoracic phenotyping for personalized cardiovascular and respiratory characterization, risk stratification, and precision medicine.

Indexed as

biomedical engineeringcardiovascular phenotypingchest wall deformitymedical devicemodified Haller indexmyocardial strainpectus excavatumpulmonary functionstress echocardiographythoracic morphometry

Identifiers

PMID42510504
PMCPMC13403693

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.