Evidence map›Paper›PMID 42540420›Full record

ArticleArchives of medical science : AMS2026

Key technical aspects and vascular access safety in membrane-based therapeutic plasma exchange for the pediatric population.

Magdalena Błasiak, Przemysław Korohoda, Katarzyna Zachwieja, Dorota Drożdż, Karina Madej-Świątkowska, Ewelina Jarosz-Wójcik, Monika Miklaszewska

Abstract read
In one paragraph

Article in Archives of medical science : AMS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Magdalena BłasiakDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.
Przemysław KorohodaDepartment of Electronics, Faculty of Computer Science, Electronics and Telecommunications, AGH University of Science and Technology, Krakow, Poland.
Katarzyna ZachwiejaDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.
Dorota DrożdżDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.
Karina Madej-ŚwiątkowskaDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.
Ewelina Jarosz-WójcikDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.
Monika MiklaszewskaDepartment of Pediatric Nephrology and Hypertension, University Children's Hospital, Krakow, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Therapeutic plasma exchange (TPE) is a widely used extracorporeal blood purification procedure. While its principles are similar across age groups, the technical complexity and risks are heightened in pediatric patients due to unique technical considerations. This study assessed the safety regarding both technical and clinical complications of vascular access and membrane-based TPE filters in a pediatric population at a single center. Material and methods: This retrospective cohort study reviewed charts of patients undergoing TPE at a level 3 referral center over 25 years. Results: The study involved 178 patients undergoing a total of 740 procedures during 214 sessions, predominantly using femoral vascular access. The median duration of the entire TPE sessions (treated as a surrogate for catheter lifespan) was 118.5 h. Technical complications occurred in 20.8% of procedures (31.6% of events), while clinical complications occurred in 4.2% (4.7% of events). Technical complications were nearly five times more frequent than clinical complications, with technical events being 6.7 times more common. The proportion of patients experiencing clinical complications was 15.2%. Logistic regression demonstrated that each additional day of catheter placement increased the probability of technical complications by 3%. Additionally, each year of patient age decreased the likelihood of clinical complications by 8.9%, while fresh frozen plasma (FFP) supplementation within a session increased the probability of clinical complications by 21.6%. Conclusions: Prolonged catheter use increases technical events, while FFP supplementation elevates catheter-related clinical complication risk. Advancing patient age reduces the likelihood of clinical complications, underscoring age-specific safety considerations in pediatric TPE.

Indexed as

central catheterchildrenclinical adverse effectsfiltertechnical adverse effectstherapeutic plasma exchange

Identifiers

PMID42540420
PMCPMC13426138

What Socratic holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.