Evidence map›Paper›PMID 42590734›Full record

ReviewSensors (Basel, Switzerland)2026

Carbon Nanotube-Based Gas Sensors: Sensing Mechanisms, Functional Interfaces, Gas-Specific Performance, and Flexible/Wearable Integration.

Daewoong Jung

Abstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Mechanism-to-Deployment Engineering of NOMaterials (Basel, Switzerland) · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Daewoong JungDepartment of Nanomechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, 2 Busandaehak-ro, Busan 46241, Republic of Korea.ORCID 0009-0008-0746-2052

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Carbon nanotubes (CNTs) have become one of the most widely investigated nanomaterials for gas sensing because their nearly one-dimensional geometry, large surface-to-volume ratio, hollow structure, and tunable metallic or semiconducting character allow trace adsorption events to be transduced into measurable electrical signals at or near room temperature. This review summarizes CNT-based gas sensors from a system-oriented perspective, linking four interconnected topics: (i) CNT structure, synthesis, and film/device fabrication; (ii) sensing mechanisms, including charge transfer, Schottky-barrier modulation, carrier-lifetime effects, and field-enhanced ionization; (iii) functional interfaces based on noble metals, metal oxides, conducting polymers, and graphene derivatives; and (iv) gas-specific and flexible/wearable device performance. Particular attention is given to recent room-temperature and mechanically compliant CNT-film sensors fabricated on polymer, cellulose, paper, textile, and mask substrates. Rather than cataloguing only individual response values, this review compares representative devices in terms of target gas, operating condition, sensitivity, recovery strategy, selectivity, humidity tolerance, and wearable relevance. The review concludes by discussing remaining challenges in reproducibility, selectivity, humidity compensation, recovery, power consumption, and standardization, and by outlining future directions toward robust, scalable, and intelligent CNT-enabled sensing systems.

Indexed as

carbon nanotubeschemiresistorconducting polymerflexible electronicsfunctionalizationgas sensorsmetal oxideroom-temperature sensing

Identifiers

PMID42590734
PMCPMC13469241

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.