ArticleBiomimetics (Basel, Switzerland)2026
An Underactuated Hip Exoskeleton to Assist Hip Joints Driven by a Single-Series Elastic Actuator.
Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Conventional hip exoskeletons typically employ multiple actuators to provide effective assistance to the corresponding joint, leading to an increase in the weight of the exoskeleton. Underactuated designs reduce the number of actuators, thereby lowering system weight and cost. However, existing single-motor underactuated hip exoskeletons still face challenges in achieving precise assistance and accommodating non-walking movements such as free sitting. In this work, we propose an underactuated hip exoskeleton with a series elastic actuator (SEA) and two independent cables for walking assistance. The incorporation of the SEA contributes to system safety and precise assistive force control. Furthermore, the proposed differential cable structure enables free sitting movement and allows for non-strictly symmetric hip motion. In experiments, with a target assistive force of 300 N, the proposed actuator achieves a peak force-tracking accuracy of 98.01% in walking tests, and the hip exoskeleton reduces peak muscle activation by up to 23.62% during walking.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.