ArticleBiosensors2026
A Low-Cost, Lightweight High-Frequency Ultrasound Transducer with Aluminum Electrodes and 3D-Printed Polymer Housing.
Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
There is an increasing demand for ultrasound imaging technologies, particularly wearable and portable systems, for continuous physiological monitoring applications. Although some recent flexible ultrasound devices have adopted polymer encapsulations, typical rigid transducer designs still include metal housings and costly electrodes, contributing to increased device weight and fabrication cost. To address these limitations, we developed an aluminum-electrode/3D-printed polymer-housing ultrasound transducer (APUT) utilizing a polyvinylidene fluoride piezoelectric film. Compared to a gold-electrode/metal-housing ultrasound transducer, the APUT material costs and total weight were approximately 66% and 86% lower, respectively. Acoustic evaluation revealed a center frequency of 24.5 MHz and a fractional bandwidth of 60.9%, with axial and lateral resolutions of 51 and 152 μm, respectively. Furthermore, during a 3-h pulsed operation test, the APUT exhibited an initial increase in capacitance followed by a relatively stable response, with no progressive surface-temperature increase detected within the accuracy of the measurement method. Finally, successful ex vivo imaging of chicken breast tissue confirms the APUT's biomedical applicability, highlighting its potential as a wearable, portable, and disposable ultrasound platform.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.