Evidence map›Paper›PMID 42783122›Full record

ArticleBiosensors2026

A Low-Cost, Lightweight High-Frequency Ultrasound Transducer with Aluminum Electrodes and 3D-Printed Polymer Housing.

Hyungjung Kim, Woohyun Jin, Do-Kyung Kim, Jaewoo Kim, Jeongwoo Park

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hyungjung KimDepartment of Biomedical Convergence Science and Technology, Kyungpook National University, Daegu 41566, Republic of Korea.
Woohyun JinDepartment of Biomedical Convergence Science and Technology, Kyungpook National University, Daegu 41566, Republic of Korea.
Do-Kyung KimDepartment of Advanced AI Engineering, Kangwon National University, Samcheok 25913, Republic of Korea.
Jaewoo KimDepartment of Convergence IT Engineering and Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.ORCID 0000-0002-6585-9911
Jeongwoo ParkDepartment of Biomedical Convergence Science and Technology, Kyungpook National University, Daegu 41566, Republic of Korea.ORCID 0000-0003-3366-2329

Funding

Dongil Culture and Scholarship FoundationNational Research Foundation of Korea RS-2024-00339595
6 · The paper itself

Abstract

There is an increasing demand for ultrasound imaging technologies, particularly wearable and portable systems, for continuous physiological monitoring applications. Although some recent flexible ultrasound devices have adopted polymer encapsulations, typical rigid transducer designs still include metal housings and costly electrodes, contributing to increased device weight and fabrication cost. To address these limitations, we developed an aluminum-electrode/3D-printed polymer-housing ultrasound transducer (APUT) utilizing a polyvinylidene fluoride piezoelectric film. Compared to a gold-electrode/metal-housing ultrasound transducer, the APUT material costs and total weight were approximately 66% and 86% lower, respectively. Acoustic evaluation revealed a center frequency of 24.5 MHz and a fractional bandwidth of 60.9%, with axial and lateral resolutions of 51 and 152 μm, respectively. Furthermore, during a 3-h pulsed operation test, the APUT exhibited an initial increase in capacitance followed by a relatively stable response, with no progressive surface-temperature increase detected within the accuracy of the measurement method. Finally, successful ex vivo imaging of chicken breast tissue confirms the APUT's biomedical applicability, highlighting its potential as a wearable, portable, and disposable ultrasound platform.

Indexed as

TransducersAluminumAnimalsElectrodesEquipment DesignFluorocarbon PolymersPolymersPrinting, Three-DimensionalUltrasonographyAluminumFluorocarbon PolymersPolymershigh-frequency ultrasoundlightweight transducerlow-cost transducerultrasound imagingultrasound transducer

Identifiers

PMID42783122
PMCPMC13604671

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.