Evidence map›Paper›PMID 42837396›Full record

ArticleJournal of applied clinical medical physics2026

Assessment of image quality and detectability in computed tomography: Inter-laboratory comparison of Fourier-based metrics.

Pascal Monnin, Damien Racine, Luis Ammour, Yves Barbotteau, Davide Cester, Dimitar Petrov, Kwinten Torfs, Raffaele Villa, Nicoletta Paruccini, Joël Greffier and 1 more

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Pascal MonninInstitute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland.ORCID https://orcid.org/0000-0003-1877-8171
Damien RacineInstitute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland.
Luis AmmourCHU Nantes, Nantes Université, Nantes, France.
Yves BarbotteauService d'imagerie-Hôpital Clairval, Ramsay Santé, Marseille, France.
Davide CesterDiagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zürich, Switzerland.ORCID https://orcid.org/0000-0001-6937-6127
Dimitar PetrovDepartment of Imaging and Pathology, KU Leuven, Leuven, Belgium.
Kwinten TorfsDepartment of Imaging and Pathology, KU Leuven, Leuven, Belgium.ORCID https://orcid.org/0000-0001-9622-361X
Raffaele VillaMedical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy.ORCID https://orcid.org/0000-0001-7370-2861
Nicoletta ParucciniMedical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy.
Joël GreffierIMAGINE UR UM 103, Department of Medical Imaging, Nîmes University Hospital, Montpellier University, Nîmes, France.ORCID https://orcid.org/0000-0002-1735-5129
Anaïs ViryInstitute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe task-based assessment of image quality in computed tomography (CT) is increasingly used for benchmarking, optimizing acquisition and reconstruction parameters, and predicting observers' performance. To achieve consistent and reproducible results rely on standardized methodologies and guidelines. PURPOSE: This study performed an inter-laboratory comparison to evaluate the consistency of CT image quality metrics and assess inter-laboratory variability.

methodsSix series of images of a Catphan 500 phantom were acquired at three dose levels (1.5/5.0/15.0 mGy) with two (standard and high-resolution) kernels and sent to seven independent laboratories. Participants calculated the task transfer function (TTF) for spatial resolution and noise power spectrum (NPS) for noise magnitude and texture using standardized Fourier-based analysis on the shared images. The TTFs and NPS were used in the non-prewhitening observer model without (NPW) and with eye filter (NPWE) to calculate a detectability index for small (2 mm) and large targets (10 mm).

resultsThe difference observed in TTFs resulted mainly from the different noise reduction techniques used during the calculation. The frequency corresponding to the TTF value 50% varied from 0.27 to 0.43 mm

conclusionAdapting TTF and NPS to a more complex and localized analysis of CT images with non-uniform CNRs, rather than a simple global evaluation, increases computational variability and requires a move towards more standardization of metrics. In the absence of complete standardization of image quality measurement, documentation of methods and all calculation parameters is essential for more robust evaluation of CT image quality.

Indexed as

AlgorithmsFourier AnalysisImage Processing, Computer-AssistedPhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedHumansObserver Variationcomputed tomographydetectabilityFourier‐based metricsimage qualityinter‐laboratory comparison

Identifiers

PMID42837396
PMCPMC13641360

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.