Evidence map›Paper›PMID 42877778›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2026

Attenuation Pre-Correction in Iterative PET Image Reconstruction: What is the Statistical Cost?

Yifan Hu, Kathryn Fontaine, Yassir Najmaoui, Thibault Marin, Richard E Carson

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yifan HuDepartment of Radiology and Biomedical Imaging, Yale University, Connecticut, USA.
Kathryn FontaineDepartment of Radiology and Biomedical Imaging, Yale University, Connecticut, USA.
Yassir NajmaouiDepartment of Radiology and Biomedical Imaging, Yale University, Connecticut, USA.
Thibault MarinDepartment of Radiology and Biomedical Imaging, Yale University, Connecticut, USA.
Richard E CarsonDepartment of Radiology and Biomedical Imaging, Yale University, Connecticut, USA; Department of Biomedical Engineering, Yale University, Connecticut, USA.

Funding

NeuroExplorer: Ultra-high Performance Human Brain PET Imager for Highly-resolved In Vivo Imaging of NeurochemistryU01EB029811 · NIBIB · YALE UNIVERSITY · PI CARSON, RICHARD E., LI, HONGDI · 2020 to 2024
$10.0M
Improved drug efficacy assessment using joint Bayesian estimation frameworkR01EB035093 · NIBIB · YALE UNIVERSITY · PI Thibault Marin · 2024 to 2026
$1.2M
Fulfilling the potential of next generation brain PET imaging systemsR01EB037707 · NIBIB · YALE UNIVERSITY · PI Richard E. Carson, Marc David Normandin · 2026 to 2026
$664k
NIBIB NIH HHS R01 EB035093NIBIB NIH HHS R01 EB037707NIBIB NIH HHS U01 EB029811
6 · The paper itself

Abstract

Attenuation pre-correction (APC) is an effective strategy to reduce the computational cost of iterative PET image reconstruction by decoupling object-dependent attenuation effects from the system sensitivity image. However, APC alters the statistical properties of the projection data, leading to a mismatch between the assumed Poisson likelihood and the true data distribution. In this work, we investigate the statistical cost of APC in terms of image variance increase. By modeling APC reconstruction as a misspecified likelihood problem, we derive the variance lower bound using the Godambe information matrix (GIM), which provides a principled alternative to the conventional Fisher information matrix. To enable efficient computation for large-scale three-dimensional PET systems, we introduce a zero-picosecond time-of-flight (ZPT) assumption and derive a closed-form expression for the variance ratio of APC relative to MLEM. Theoretical predictions are validated against simulations using iterative reconstruction. Simulations demonstrate that attenuation heterogeneity along the contributing lines of response is the dominant factor driving APC-induced variance increase, while the impact of TOF resolution becomes secondary for modern TOF PET systems with timing resolution on the order of 200 ps. Three-dimensional evaluations with ZPT across different scanner geometries show large increases (>100%) in lesion variance on whole-body and total-body scanners, while a more moderate increase is observed on a brain-dedicated scanner. Experimental validation using human PET data further confirms the theoretical findings. This work provides a quantitative framework for evaluating the statistical cost of APC PET reconstruction.

Indexed as

attenuation pre-correctionGodambe Information MatrixPositron Emission Tomographyvariance increasezero-picosecond time-of-flight

Identifiers

PMID42877778
PMCPMC13665234

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.