SynthesisThe Cochrane database of systematic reviews2022
Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.
Synthesis in The Cochrane database of systematic reviews, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 3 syntheses or guidelines pooled it, 33 citations in OpenAlex.
- Pharmacological interventions for asymptomatic carotid stenosis.The Cochrane database of systematic reviews · 2023 · on this mapPooled it
- Type of anaesthesia for acute ischaemic stroke endovascular treatment.The Cochrane database of systematic reviews · 2022Pooled it
- Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.The Cochrane database of systematic reviews · 2022Pooled it
- Agreement across different measurements for internal carotid artery stenosis in patients with TIA or stroke in the CONVINCE trial.European radiology · 2026Trial
- Inter-reader agreement in multimodality imaging of carotid plaque-RADS: considerations for modality selection.Insights into imaging · 2026Article
- Diagnostic Performance of Duplex Ultrasonography in Post-Radiation Common Carotid Artery Stenosis: A Cross-Sectional Validation Study.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026Article
- Neurocognitive Changes and Cerebral Blood Flow in Patients with Symptomatic Carotid Artery Stenosis before and after Carotid Endarterectomy.Journal of Korean Neurosurgical Society · 2026Article
- Vector Flow Imaging for Carotid Artery Stenosis Assessment: A Scoping Review.Diagnostics (Basel, Switzerland) · 2026Review
- Duplex ultrasound in severe carotid stenosis: diagnostic performance for differentiating near-occlusion subtypes from conventional high-grade stenosis.Neuroradiology · 2026Article
- Automated Detection of Carotid Artery Stenosis Using a Sensitive Accelerometer Wearable Sensor and Interpretable Machine Learning.Biosensors · 2026Article
- Carotid intima-media thickness in relation to primary open-angle glaucoma: epidemiological and structural evidence from a cross-sectional study.BMJ open ophthalmology · 2026Article
- Hemi-ellipsoid formula enables accurate assessment of carotid plaque volume and atherosclerotic burden.Scientific reports · 2026Article
- Article
- A comprehensive scoping review of existing carotid duplex ultrasound scanning and reporting protocols: identifying gaps and opportunities for standardization of practice in low-income countries.Journal of ultrasound · 2025Article
- Duplex ultrasound may lead to misclassification of carotid artery stenosis.Journal of vascular surgery · 2025Article
- DSA Versus Noninvasive Imaging in Revascularization Referral for Recently Symptomatic Carotid Stenosis.Stroke (Hoboken, N.J.) · 2025Article
- The Effect of Lesion Length on Doppler Velocities Used Routinely to Determine Carotid Stenosis Cross-Sectional Severity.Diagnostics (Basel, Switzerland) · 2025Article
- Non-contrast-enhanced MR-angiography of Extracranial Arteries in Acute Ischemic Stroke at 1.5 Tesla Using Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT).Clinical neuroradiology · 2025Article
- Contrast-enhanced carotid ultrasound improves vulnerable plaque detection in acute central retinal artery occlusion: a propensity score-matched study.Frontiers in cardiovascular medicine · 2025Article
- Evaluation of Carotid Stenosis in a High-Stroke-Risk Population by Hemodynamic Dual-Parameters Based on Ultrasound Vector Flow Imaging.Brain and behavior · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCarotid artery stenosis is an important cause of stroke and transient ischemic attack. Correctly and rapidly identifying patients with symptomatic carotid artery stenosis is essential for adequate treatment with early cerebral revascularization. Doubts about the diagnostic value regarding the accuracy of duplex ultrasound (DUS) and the possibility of using DUS as the single diagnostic test before carotid revascularization are still debated.
objectivesTo estimate the accuracy of DUS in individuals with symptomatic carotid stenosis verified by either digital subtraction angiography (DSA), computed tomography angiography (CTA), or magnetic resonance angiography (MRA). SEARCH
methodsWe searched CRDTAS, CENTRAL, MEDLINE (Ovid), Embase (Ovid), ISI Web of Science, HTA, DARE, and LILACS up to 15 February 2021. We handsearched the reference lists of all included studies and other relevant publications and contacted experts in the field to identify additional studies or unpublished data. SELECTION CRITERIA: We included studies assessing DUS accuracy against an acceptable reference standard (DSA, MRA, or CTA) in symptomatic patients. We considered the classification of carotid stenosis with DUS defined with validated duplex velocity criteria, and the NASCET criteria for carotid stenosis measures on DSA, MRA, and CTA. We excluded studies that included < 70% of symptomatic patients; the time between the index test and the reference standard was longer than four weeks or not described, or that presented no objective criteria to estimate carotid stenosis. DATA COLLECTION AND ANALYSIS: The review authors independently screened articles, extracted data, and assessed the risk of bias and applicability concerns using the QUADAS-2 domain list. We extracted data with an effort to complete a 2 × 2 table (true positives, true negatives, false positives, and false negatives) for each of the different categories of carotid stenosis and reference standards. We produced forest plots and summary receiver operating characteristic (ROC) plots to summarize the data. Where meta-analysis was possible, we used a bivariate meta-analysis model. MAIN
resultsWe identified 25,087 unique studies, of which 22 were deemed eligible for inclusion (4957 carotid arteries). The risk of bias varied considerably across the studies, and studies were generally of moderate to low quality. We narratively described the results without meta-analysis in seven studies in which the criteria used to determine stenosis were too different from the duplex velocity criteria proposed in our protocol or studies that provided insufficient data to complete a 2 × 2 table for at least in one category of stenosis. Nine studies (2770 carotid arteries) presented DUS versus DSA results for 70% to 99% carotid artery stenosis, and two (685 carotid arteries) presented results from DUS versus CTA in this category. Seven studies presented results for occlusion with DSA as the reference standard and three with CTA as the reference standard. Five studies compared DUS versus DSA for 50% to 99% carotid artery stenosis. Only one study presented results from 50% to 69% carotid artery stenosis. For DUS versus DSA, for < 50% carotid artery stenosis, the summary sensitivity was 0.63 (95% confidence interval [CI] 0.48 to 0.76) and the summary specificity was 0.99 (95% CI 0.96 to 0.99); for the 50% to 69% range, only one study was included and meta-analysis not performed; for the 50% to 99% range, the summary sensitivity was 0.97 (95% CI 0.95 to 0.98) and the summary specificity was 0.70 (95% CI 0.67 to 0.73); for the 70% to 99% range, the summary sensitivity was 0.85 (95% CI 0.77 to 0.91) and the summary specificity was 0.98 (95% CI 0.74 to 0.90); for occlusion, the summary sensitivity was 0.91 (95% CI 0.81 to 0.97) and the summary specificity was 0.95 (95% CI 0.76 to 0.99). For sensitivity analyses, excluding studies in which participants were selected based on the presence of occlusion on DUS had an impact on specificity: 0.98 (95% CI 0.97 to 0.99). For DUS versus CTA, we found two studies in the range of 70% to 99%; the sensitivity varied from 0.57 to 0.94 and the specificity varied from 0.87 to 0.98. For occlusion, the summary sensitivity was 0.95 (95% CI 0.80 to 0.99) and the summary specificity was 0.91 (95% CI 0.09 to 0.99). For DUS versus MRA, there was one study with results for 50% to 99% carotid artery stenosis, with a sensitivity of 0.88 (95% CI 0.70 to 0.98) and specificity of 0.60 (95% CI 0.15 to 0.95); in the 70% to 99% range, two studies were included, with sensitivity that varied from 0.54 to 0.99 and specificity that varied from 0.78 to 0.89. We could perform only a few of the proposed sensitivity analyses because of the small number of studies included. AUTHORS'
conclusionsThis review provides evidence that the diagnostic accuracy of DUS is high, especially at discriminating between the presence or absence of significant carotid artery stenosis (< 50% or 50% to 99%). This evidence, plus its less invasive nature, supports the early use of DUS for the detection of carotid artery stenosis. The accuracy for 70% to 99% carotid artery stenosis and occlusion is high. Clinicians should exercise caution when using DUS as the single preoperative diagnostic method, and the limitations should be considered. There was little evidence of the accuracy of DUS when compared with CTA or MRA. The results of this review should be interpreted with caution because they are based on studies of low methodological quality, mainly due to the patient selection method. Methodological problems in participant inclusion criteria from the studies discussed above apparently influenced an overestimated estimate of prevalence values. Most of the studies included failed to precisely describe inclusion criteria and previous testing. Future diagnostic accuracy studies should include direct comparisons of the various modalities of diagnostic tests (mainly DUS, CTA, and MRA) for carotid artery stenosis since DSA is no longer considered to be the best method for diagnosing carotid stenosis and less invasive tests are now used as reference standards in clinical practice. Also, for future studies, the participant inclusion criteria require careful attention.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.